Upgraded acceptance criteria from transient thermography control for the W7-X divertor target elements

作者:Missirlian M*; Boscary J; Guigon R; Schlosser J; Durocher A; Greuner H
来源:Fusion Engineering and Design, 2009, 84(7-11): 1317-1322.
DOI:10.1016/j.fusengdes.2008.12.080

摘要

The commissioning of plasma-facing component fields needs advanced non-destructive methods to detect in a reliable way the defects, which can impair the component performances and/or integrity during operation. Within this framework, CEA developed a dedicated non-destructive examination method based on active infrared thermography (SATIR facility) to inspect the bonding between armour material and metallic heat sink. Used with successful in the commissioning of the toroidal pump limiter of Tore Supra, this technique was applied in the frame of the pre-series activities of the Wendelstein 7-X high heat flux divertor elements to assess the bonding quality of the delivered components. This paper presents the methodology adopted to define an acceptance criterion based on SATIR test bed possibly applied for a serial inspection of the Wendelstein 7-X elements. Using the well-tried acceptance test based on the DTref_max parameter, the new method includes advanced data post-processing techniques from thermo-signal SATIR and a data merging method to help the decision-making and to optimise the reliability of the binary response expected for a final decision in terms of acceptance test.

  • 出版日期2009-6
  • 单位中国地震局

全文