Adaptive postprocessing techniques for myocardial tissue tracking with displacement-encoded MR imaging

作者:Wen Han*; Marsolo Keith A; Bennett Eric E; Kutten Kwame S; Lewis Ryan P; Lipps David B; Epstein Neal D; Plehn Jonathan F; Croisille Pierre
来源:Radiology, 2008, 246(1): 229-240.
DOI:10.1148/radiol.2461070053

摘要

The purpose of this study was to prospectively assess the effects of two adaptive postprocessing techniques on the evaluation of myocardial function with displacement-encoded magnetic resonance (MR) imaging, including sensitivity for abnormal wall motion, with two-dimensional echocardiography as the reference standard. Sixteen patients (11 men, five women; age range, 26-74 years) and 12 volunteers (six men, six women; age range, 29-53 years) underwent breath-hold MR imaging. Institutional review board approval and informed consent were obtained. Adaptive phase-unwrapping and spatial filtering techniques were compared with conventional phase-unwrapping and spatial filtering techniques. Use of the adaptive techniques led to a reduced rate of failure with the phase-unwrapping technique from 18.9% to 0.6% (P < .001), resulted in lower variability of segmental strain measurements among healthy volunteers (P < .001 to P < .02), and increased the sensitivity of quantitative detection of abnormal segments in patients from 82.5% to 87.7% (P = .034). The adaptive techniques improved the semiautomated postprocessing of displacement-encoded cardiac images and increased the sensitivity of detection of abnormal wall motion in patients.

  • 出版日期2008-1