Adiabatic sweep pulses for earth's field NMR with a surface coil

作者:Conradi Mark S; Altobelli Stephen A; Sowko Nicholas J; Conradi Susan H; Fukushima Eiichi
来源:Journal of Magnetic Resonance, 2018, 288: 23-27.
DOI:10.1016/j.jmr.2017.11.018

摘要

Adiabatic NMR sweep pulses are described for inversion and excitation in very low magnetic fields B-0 and with broad distribution of excitation field amplitude B-0. Two aspects distinguish the low field case: (1) when B-1 is comparable to or greater than B-0, the rotating field approximation fails and (2) inversion sweeps cannot extend to values well below the Larmor frequency because they would approach or pass through zero frequency. Three approaches to inversion are described. The first is a conventional tangent frequency sweep down to the Larmor frequency, a 180 degrees phase shift, and a sweep back up to the starting frequency. The other two are combined frequency and amplitude sweeps covering a narrower frequency range; one is a symmetric sweep from above to below the Larmor frequency and the other uses a smooth decrease of B-1 immediately before and after the 180 degrees phase shift. These two AM/FM sweeps show excellent inversion efficiencies over a wide range of B-1, a factor of 30 or more. We also demonstrate an excitation sweep that works well in the presence of the same wide range of B-1. We show that the primary effect of the counter-rotating field (i.e., at low B-0) is that the magnetization suffers large, periodic deviations from where it would be at large B-0. Thus, successful sweep pulses must avoid any sharp features in the amplitude, phase, or frequency.

  • 出版日期2018-3