Applying ATP bioluminescence to design and evaluate a successful new intensive care unit cleaning programme

作者:Chan M C; Lin T Y; Chiu Y H; Huang T F; Chiu S K; Liu T L; Hung P S; Chang C M; Lin J C*
来源:Journal of Hospital Infection, 2015, 90(4): 344-346.
DOI:10.1016/j.jhin.2015.04.008

摘要

This was a two-phase prospective intervention study in the cardiology intensive care unit (CICU) and medical intensive care unit (MICU) and of a public 1800-bed medical centre in Taiwan. In phase I, cleaning efficacy was monitored by ATP bioluminescence after daily morning cleaning, and only 43.9% of 221 tested surfaces passed. The baseline data were used to define an intervention consisting of a new cleaning protocol as well as a new education/training programme. In phase II, following the intervention, 88.1% of 270 surfaces were found to be clean. The combined infection rate in the CICU and MICU showed a statistically significant decrease of 49.7%.