摘要
A collinear wave mixing technique was developed to detect micro-cracks in samples by measuring the mixing of two ultrasonic sinusoidal waves. The bispectrum was used to process the nonlinear response. Experiments were conducted to investigate the influence of excitation parameters, such as driving frequency and time delay, on intermodulation among ultrasonic waves and defects. Mixing components were tracked for varying frequency or time delay, and the nonlinear response was measured at fixed frequencies and time delay. The driving frequency was found to strongly affect micro-crack detection; the optimal driving frequency corresponded to maximum amplitudes of sum and difference frequency sidebands. The time-delay dependence of the amplitude of mixing components allowed the location of defects throughout a sample.
- 出版日期2014-3
- 单位北京工业大学