Analysis of acyclovir in vitreous humor by a validated HPLC method

作者:Silva G R; Caldeira A S P; Damico F M; Takahashi B S; Silva Cunha A; Fialho S L*
来源:Pharmazie, 2013, 68(4): 235-239.
DOI:10.1691/ph.2013.2153

摘要

An HPLC-UV method was developed and validated for the determination of acyclovir in vitreous humor. The method was carried out in isocratic mode using 0.02 mol/L acetic acid/methanol (95:5) as mobile phase, a C18 column at 25 degrees C and UV detection at 254 nm. The method was linear (r(2) %26gt;0.99) over the range of 35-700 mu g/mL, precise (RSD %26lt; 5%), accurate (recovery ranged from 98.18 to 99.64%), robust, selective regarding of the vitreous humor, and robust remaining unaffected by deliberate variations in relevant parameters. The validated HPLC-UV method can be successfully applied to determine acyclovir directly injected into the vitreous cavity of rabbits%26apos; eye.

  • 出版日期2013-4