摘要

A three-dimensional Environmental Fluid Dynamics Code model was developed for a 17-km segment of the Mobile River, Alabama, USA. The model external forcing factors include river inflows from upstream, tides from downstream, and atmospheric conditions. The model was calibrated against measured water levels, velocities, and temperatures from 26 April to 29 August 2011. The Nash-Sutcliffe coefficients for water levels were greater than 0.94 and for water temperatures ranged from 0.88 to 0.99. The calibrated model was extended approximately 13 km upstream for simulating unsteady flow, dye, and temperature distributions in the Mobile River under different upstream inflows and downstream harmonic tides. Velocity profiles and distributions of flow, dye, and temperature at various locations were analyzed and show that flow recirculation could only occur under small inflow (50 m(3) s(-1)) when downstream tides control the flow pattern in the Mobile River. The model results reveal complex interactions among discharges from a power plant, inflows, and tides.

  • 出版日期2015-10-3