摘要

A fault-tolerant technique for motor-drive systems is introduced in this paper. The technique is merely presented for ac motors with Delta-connected circuits in their stator windings. In this technique, the faulty phase is isolated by solid-state switches after the occurrence of a failure in one of the stator phases. Then, the fault-tolerant technique manages current-flow in the remaining healthy phases. This technique is to significantly mitigate torque pulsations, which are caused by an open-Delta configuration in the stator windings. The performance of the fault-tolerant technique was experimentally verified using a 5-hp 460-V induction motor-drive system and the results are presented in this paper.

  • 出版日期2011-6