Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry

作者:Yokoay Claros Chacaltana Flor Diana; Tadeu Pigatto Joao Antonio; Denardin Ione Terezinha
来源:Ciencia Rural, 2016, 46(8): 1466-1471.
DOI:10.1590/0103-8478cr20151206

摘要

The aim of this research was to measure the intraocular pressure (IOP) of normal chinchilla eyes using the rebound tonometer. A further aim was to assess whether there were differences in the values of intraocular pressure in relation to animals age, gender and time of day. Thirty-six chinchillas were divided into three groups of 12 chinchillas each, by age: Group I (2-6-month-old), Group II (20 and 34 months) and Group III (37 and 135 months). Ophthalmic examination was performed previously by Schirmer tear test, slit lamp biomicroscopy, indirect ophthalmoscopy and fluorescein test in all chinchillas. Three measurements of intraocular pressure were assessed on the same day (7, 12 and 19h). Tonometry was performed on both eyes using the rebound tonometer after calibration in "p" mode. Statistical analysis was performed with SigmaPlot for Windows. The mean IOP for groups I, II and III were 2.47 +/- 0.581mmHg, 2.47 +/- 0.581mmHg and 2.51 +/- 0.531mmHg, respectively. No significant differences were reported between age and IOP and no significant differences were reported between the time of day and IOP. The IOP in chinchillas did not differ significantly between genders or ages of the animals, and did not change with time of day.

  • 出版日期2016-8

全文