作者:Gignac Paul M; Kley Nathan J; Clarke Julia A; Colbert Matthew W; Morhardt Ashley C; Cerio Donald; Cost Ian N; Cox Philip G; Daza Juan D; Early Catherine M; Echols M Scott; Henkelman R Mark; Herdina A Nele; Holliday Casey M; Li Zhiheng; Mahlow Kristin; Merchant Samer; Mueller Johannes; Or**on Courtney P; Paluh Daniel J; Thies Monte L; Tsai Henry P; Witmer Lawrence M
来源:Journal of Anatomy, 2016, 228(6): 889-909.
DOI:10.1111/joa.12449

摘要

Morphologists have historically had to rely on destructive procedures to visualize the three-dimensional (3-D) anatomy of animals. More recently, however, non-destructive techniques have come to the forefront. These include X-ray computed tomography (CT), which has been used most commonly to examine the mineralized, hard-tissue anatomy of living and fossil metazoans. One relatively new and potentially transformative aspect of current CT-based research is the use of chemical agents to render visible, and differentiate between, soft-tissue structures in X-ray images. Specifically, iodine has emerged as one of the most widely used of these contrast agents among animal morphologists due to its ease of handling, cost effectiveness, and differential affinities for major types of soft tissues. The rapid adoption of iodine-based contrast agents has resulted in a proliferation of distinct specimen preparations and scanning parameter choices, as well as an increasing variety of imaging hardware and software preferences. Here we provide a critical review of the recent contributions to iodine-based, contrast-enhanced CT research to enable researchers just beginning to employ contrast enhancement to make sense of this complex new landscape of methodologies. We provide a detailed summary of recent case studies, assess factors that govern success at each step of the specimen storage, preparation, and imaging processes, and make recommendations for standardizing both techniques and reporting practices. Finally, we discuss potential cutting-edge applications of diffusible iodine-based contrast-enhanced computed tomography (diceCT) and the issues that must still be overcome to facilitate the broader adoption of diceCT going forward.

  • 出版日期2016-6