摘要

This paper presents a wind energy assessment and a wind farm simulation in the city of Triunfo in the state of Pernambuco in the northeast region of Brazil. The wind data were obtained from the SONDA (Sistema de Organizacao Nacional de Dados Ambientais) project's meteor station (wind speed, wind direction and temperature) at both heights of 50 m during a period of time of 30 months. The Triunfo wind characterization and wind power potential assessment study shows an average wind speed (V) of 11.27 m/s (predominant Southeast wind direction), an average wind power density (P/A(T)) of 1.672 W/m(2) and Weibull parameters shape (K) and scale (A) respectively equal to 2.0 and 12.7 m/s. Those values demonstrate an important wind potential in this region for future wind farm prospection. The wind farm (TRI) was simulated by using 850 kW wind turbines given a total of 20 MW installed. The simulated results show(s) an AEP (annual energy produced) of 111.4 GWh, a capacity factor (C(f)) of 62% and a total of 5.462 h of operation by year (full load hours). The economical simulated results show(s) a Pay-back of 3 years Internal Rate of Return (IRR) of 47% and Net Present Value (NPV) of 85.506 k(sic) (both in a period of time of 20 years).

  • 出版日期2010-12