摘要

The aim of this study was to demonstrate characteristic imaging and accurate evaluation of blood perfusion in early stage of hepatic alveolar echinococcosis (HAE) by contrast-enhanced ultrasonography (CEUS). The early stage of experimentally induced secondary HAE in 45 rats was studied. Thirty-six HAE lesions in 33 rats, confirmed by pathologic examination, were examined by ultrasound (US), color Doppler flow imaging (CDFI) and then CEUS. Thirty-three lesions were found in 30 rats by US, and 30 lesions were detected in 27 rats by CEUS. The sensitivity of US and CEUS was 92% (95% CI 76%-98%) and 82% (95% CI 65%-93%), respectively. US imaging characteristics were categorized into four types: hyperechoic spot (type 1, 45.5%, 15/33), granular hyperechoic spots (type 2, 12.1%, 4/33), hyperechoic lesion (type 3, 30.3%, 10/33) and mixed pattern (type 4, 12.1%, 4/33). CDFI failed to detect blood flow signals in any lesions. CEUS results for 30 lesions showed ring enhancement in the peripheral area during the arterial phase and no filling effect in either the portal or the delayed phase (46.7%, 14/30); ring enhancement combined with central septa enhancement during the arterial phase and portal venous phase (46.7, 14/30), and no enhancement (6.6%, 2/30). The enhanced area, confirmed by pathologic examination, was an inflammatory reaction belt surrounding the lesion. The results of this study suggest that US, with high sensitivity, can be used as a screening method for early HAE lesions in the animal model, while CEUS can be used for displaying the peripheral blood perfusion and vesicle structure. (E-mail: dr_lwyykdx@163.

全文