摘要

In this paper, an engineering method for the power flow assessment of a position-controlled servomechanism is outlined. The considered system is composed of a permanent magnet synchronous motor coupled to a standard power converter, and directly connected to a slider crank mechanism. After the accurate description of a consistent power flow model, a sequential identification technique is discussed, which allows to determine the dynamic parameters of linkage, electric motor and electronic driver by means of non-invasive experimental measures. The proposed model allows to accurately predict the major sources of power loss within the system.

  • 出版日期2016-4