Atomic Fountain Clock With Very High Frequency Stability Employing a Pulse-Tube-Cryocooled Sapphire Oscillator

作者:Takamizawa Akifumi*; Yanagimachi Shinya; Tanabe Takehiko; Hagimoto Ken; Hirano Iku; Watabe Ken ichi; Ikegami Takeshi; Hartnett John G
来源:IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2014, 61(9): 1463-1469.
DOI:10.1109/TUFFC.2014.3060

摘要

The frequency stability of an atomic fountain clock was significantly improved by employing an ultra-stable local oscillator and increasing the number of atoms detected after the Ramsey interrogation, resulting in a measured Allan deviation of 8.3 x 10(-14) tau(-1/2). A cryogenic sapphire oscillator using an ultra-low-vibration pulse-tube cryocooler and cryostat, without the need for refilling with liquid helium, was applied as a local oscillator and a frequency reference. High atom number was achieved by the high power of the cooling laser beams and optical pumping to the Zeeman sublevel m(F) = 0 employed for a frequency measurement, although vapor-loaded optical molasses with the simple (001) configuration was used for the atomic fountain clock. The resulting stability is not limited by the Dick effect as it is when a BVA quartz oscillator is used as the local oscillator. The stability reached the quantum projection noise limit to within 11%. Using a combination of a cryocooled sapphire oscillator and techniques to enhance the atom number, the frequency stability of any atomic fountain clock, already established as primary frequency standard, may be improved without opening its vacuum chamber.

  • 出版日期2014-9