MEKC determination of IgG in human serum via a pH-mediated acid stacking method

作者:Wu Yi Wei*; Liu Jun Feng; Deng Zhen Li; Zhang Jing; Jiang Feng; Xiong Kun; Zhang Haili
来源:Journal of Separation Science, 2010, 33(19): 3068-3074.
DOI:10.1002/jssc.201000144

摘要

An on-column preconcentration technique, pH-mediated acid stacking, was used in this study to improve the sensitivity of MEKC-UV analysis of IgG in human serum. Various parameters affecting pH-mediated acid stacking were optimized systematically. To eliminate the matrix interferences of human serum and to combine the sample pretreatment procedure with the detection methodology, silica-coated Fe(3)O(4) magnetic nanoparticles modified with N-(2-aminoethyl)-3-aminopropyl-trimethoxysilane were prepared and employed as solid phase extraction adsorbent to remove the abundant HSA from human serum. HSA was quantitatively removed by silica-coated Fe(3)O(4) magnetic nanoparticles modified with N-(2-aminoethyl)-3-aminopropyl-trimethoxysilanes without retaining IgG at pH 9.3. Under the optimum conditions, the sensitivity of IgG was improved 40.3-fold using a 100 s electrokinetic injection as compared with a 6 s hydrodynamic injection. The detection limit of IgG was found to be 0.1 mg/L, and the proposed method was successfully applied for the determination of IgG in human serum with satisfactory results.

  • 出版日期2010-9
  • 单位湖北师范大学