摘要

A carbon paste electrode bulk-modified with ammonium tetrafluorobismuthate (BiF(4)-CPE) was developed and examined in the anodic stripping voltatnmetric mode for measurement of selected trace heavy metals. The BiF4-CPE has revealed a favorable performance in more acidic solutions (pH 0.5-2.5) in the presence of dissolved oxygen for Cd(II) and Pb(II) as model metal ions at the low mu g L(-1) concentration level. In comparison with the bismuth-oxide bulk-modified carbon paste electrode and the other two bismuth film-plated carbonaceous substrate electrodes examined, the BiF(4)-CPE proved to be another attractive variant of the environmentally friendly bismuth-based electrodes, particularly convenient for analysis of acidified water samples.

  • 出版日期2010-7