摘要

Introduction: Similar to magnetic resonance imaging (MRI), electrical impedance myography (EIM) is dependent on the presence and location of water in muscle to assess neuromuscular diseases. We compared the 2 technologies in mdx mice to better understand their relationship. Methods: EIM and MRI, using T2 relaxation and diffusion-weighted imaging (DWI), were performed on the gastrocnemius of 10 mdx and 10 wildtype mice. Muscle function and tissue composition measurements were compared with the EIM and MRI data. Results: EIM reactance and T2 relaxation mapping can discriminate healthy from diseased mice (P < 0.001 for both), but DWI could not. Both T2 relaxation and EIM reactance also correlated closely with muscle function/composition and with each other. Conclusion: Given the low cost of EIM and the simplicity of application, it may be a valuable alternative to muscle MRI in Duchenne muscular dystrophy, where simple cumulative indices of muscle health are being sought.

  • 出版日期2015-10