Association of Parathyroid Gland Biopsy Excision Technique With Ex Vivo Radiation Counts During Radioguided Parathyroid Surgery

作者:Hinson Andrew M; Lawson Bradley R; Franco Aime T; Stack Brendan C Jr*
来源:JAMA Otolaryngology-Head & Neck Surgery, 2017, 143(6): 595-600.
DOI:10.1001/jamaoto.2016.4635

摘要

IMPORTANCE Parathyroid biopsy represents a means for normal and hyperfunctional glands to be distinguished intraoperatively. However, no data exist to guide surgeons regarding how much of a parathyroid gland must be biopsied to satisfy the 20% rule. OBJECTIVE To quantify the relative proportion of a hyperfunctional parathyroid gland that must be evaluated with the gamma probe to satisfy the 20% rule. DESIGN, SETTING, AND PARTICIPANTS A retrospective review of surgical data for 24 consecutive patients (16 women, 18 men; mean [SD] age, 66.6 [10] years; range, 51-83 years) who underwent surgery for primary hyperparathyroidism between May and October, 2015, in a tertieary academic medical center. MAIN OUTCOMES AND MEASURES Extirpated parathyroid glandswere sectioned into parallel or pie-shaped biopsies and evaluated ex vivo with a gamma probe to determine what percentage of a hyperfunctional gland must be sampled to meet the Norman 20% rule. The hypothesis was formulated during data collection. RESULTS In total, 253 ex vivo biopsy specimens were obtained from 33 surgically removed parathyroid glands. Parathyroid biopsies satisfied the 20% rule with an accuracy that depended on the relative proportion of the parent gland represented: half or more (96.6%; 95% CI, 91.7%-100.0%), a quarter to one-half (87.0%; 95% CI, 79.3%-94.7%), less than a quarter (63.6%; 95% CI, 54.5%-72.8%). When less than a quarter of the gland was removed, pie-shaped biopsies were more likely to satisfy the 20% rule compared with parallel biopsies of the same weight (78.4% vs 56.2%; absolute difference, 22.2%; 95% CI, 4.7%-39.7%). CONCLUSIONS AND RELEVANCE Unless half of a parathyroid gland is biopsied during radioguided parathyroidectomy, the 20% rule cannot reliably rule out the presence of a hyperfunctional parathyroid lesion. Pie-shaped biopsies originating from the center of the gland are associated with a lower rate of false-negative results compared with peripheral biopsies of similar size. Pie-shaped biopsies and biopsy of half or more of each nonexcised parathyroid gland for ex vivo counts may increase the risk of remnant devascularization and resultant hypoparathyroidism.

  • 出版日期2017-6