A new MRI rating scale for progressive supranuclear palsy and multiple system atrophy: validity and reliability

作者:Rolland Yan; Verin Marc; Payan Christine A; Duchesne Simon; Kraft Eduard; Hauser Till K; Jarosz Josef; Deasy Neil; Defevbre Luc; Delmaire Christine; Dormont Didier; Ludolph Albert C; Bensimon Gilbert; Leigh P Nigel*
来源:Journal of Neurology Neurosurgery and Psychiatry, 2011, 82(9): 1025-1032.
DOI:10.1136/jnnp.2010.214890

摘要

Aim To evaluate a standardised MRI acquisition protocol and a new image rating scale for disease severity in patients with progressive supranuclear palsy (PSP) and multiple systems atrophy (MSA) in a large multicentre study.
Methods The MRI protocol consisted of two-dimensional sagittal and axial T1, axial PD, and axial and coronal T2 weighted acquisitions. The 32 item ordinal scale evaluated abnormalities within the basal ganglia and posterior fossa, blind to diagnosis. Among 760 patients in the study population (PSP=362, MSA=398), 627 had per protocol images (PSP=297, MSA=330). Intra-rater (n=60) and inter-rater (n=555) reliability were assessed through Cohen's statistic, and scale structure through principal component analysis (PCA) (n=441). Internal consistency and reliability were checked. Discriminant and predictive validity of extracted factors and total scores were tested for disease severity as per clinical diagnosis.
Results Intra-rater and inter-rater reliability were acceptable for 25 (78%) of the items scored (>= 0.41). PCA revealed four meaningful clusters of covarying parameters (factor (F) F1: brainstem and cerebellum; F2: midbrain; F3: putamen; F4: other basal ganglia) with good to excellent internal consistency (Cronbach alpha 0.75-0.93) and moderate to excellent reliability (intraclass coefficient: F1: 0.92; F2: 0.79; F3: 0.71; F4: 0.49). The total score significantly discriminated for disease severity or diagnosis; factorial scores differentially discriminated for disease severity according to diagnosis (PSP: F1-F2; MSA: F2-F3). The total score was significantly related to survival in PSP (p<0.0007) or MSA (p<0.0005), indicating good predictive validity.
Conclusions The scale is suitable for use in the context of multicentre studies and can reliably and consistently measure MRI abnormalities in PSP and MSA.

  • 出版日期2011-9