摘要

This study evaluated radiotherapy techniques with 15 cases for simultaneous integrated boost to treat whole left breast and tumor bed following breast conserving surgery. Treatment plans were generated using three techniques: volumetric modulated arc therapy (VMAT) with a partial arc of 190 degrees (1ARC), VMAT with two tangential mini-arcs of 50 degrees each (2TARC) and intensity modulated radiation therapy with four fixed angle fields (4IMRT). Dosimetric parameters for the whole breast (Target), the boost tumor bed (Boost), and surrounding normal organs were compared. Chair Index (CHI) was introduced to evaluate the dose homogeneity in Target given the two levels of prescription dose. The dose coverage in Target was better in 1ARC and 2TARC than that in 4IMRT. The mean CHI in 1ARC (2.47) and 2TARC (2.62) were higher than that in 4IMRT (1.71, p < 0.05), and this indicated the dose homogeneity of Target was better in 1ARC and 2TARC than that in 4IMRT. The mean doses to right lung, and contralateral breast in 4IMRT were lower than those in 2TARC but the differences between them were small. 2TARC was better than 4IMRT with respect to the dose to ipsilateral lung and heart. Overall, 2TARC was optimal among three techniques.