摘要

Quantitative analysis of CaO in limestone mining is mandatory, not only for ore exploration, but also for grade control. A partial least squares regression (PLSR) CaO estimation technique was developed for limestone mining. The proposed near-infrared spectroscopy (NIR)-based method uses reflectance spectra of the rock sample surface in the visible to short-wave infrared wavelength regions (350-2500 nm (4000-28,571 cm(-1))) without the need to crush and pulverize the rock samples. The root mean square (RMS) error of CaO estimation using limestone ore fragment was 1.2%. The CaO content estimated by the PLSR method was used to predict average CaO content of composite samples with a sample size of 15, which resulted in an RMS error of 0.3%. The prediction accuracy with moisture on sample surfaces was also examined to find out if the NIR-based method showed a similar RMS error. Results suggest that the NIR technique can be used as a rapid assaying method in limestone workings with or without the presence of groundwater.