摘要

A fiber optic sensing system for simultaneous measurement of refractive index and temperature, based on a hybrid fiber Bragg grating/long-period grating arrangement is described. The experimental results show that this setup has a good performance in terms of linearity and sensitivity, the ratiometric output changes 4%/0.001 RIU and 3.6%/degrees C, respectively. The sensor resolution for the refractive index is approximate to 2 x 10(-5) RIU. The simultaneous measurement of the refractive index and temperature was demonstrated. The sensing configuration has the ability to be read-out in reflection and works in the telecommunications

  • 出版日期2009