摘要

In this study, a novel intelligent relaying scheme is proposed for fault classification and faulted phase selection using magnitude of differential power (MODP). The DP is the multiplication of difference between the magnitude of the real and estimated voltage and current phasors. The MODP for each phase is used as an input data to the data mining model known as decision tree (DT). The DT is used to generate thresholds to detect and classify the faults, since determination of robust thresholds is an important challenge in protective relay engineering. The proposed method has been tested for different operating modes of single-circuit transmission line in Simulink/MATLAB software. Simulation results indicate that the proposed method is able to detect and classify the faults with acceptable accuracy, in less than half cycle.

  • 出版日期2017-8-3