A novel mouse model of in situ stenting

作者:Chamberlain Janet*; Wheatcroft Mark; Arnold Nadine; Lupton Henry; Crossman David C; Gunn Julian; Francis Sheila
来源:Cardiovascular Research, 2010, 85(1): 38-44.
DOI:10.1093/cvr/cvp262

摘要

Aims Animal models of stenting are mostly limited to larger animals or involve substantial abdominal surgery in rodents. We aimed to develop a simple, direct model of murine stenting. Methods and results We designed a miniature, self-expanding, nitinol wire coil stent that was pre-loaded into a metal stent sheath. This was advanced into the abdominal aorta of the mouse, via femoral access, and the stent deployed. In-stent restenosis was investigated at 1, 3, 7, and 28 days post-stenting. The model was validated by investigation of neointima formation in mice deficient in signalling via the interleukin-1 receptor (IL-1R1), compared with other injury models. Ninety-two per cent of mice undergoing the procedure were successfully stented. All stented vessels were patent. Inflammatory cells were seen in the adventitia and around the stent strut up to 3 days post-stenting. At 3 days, an early neointima was present, building to a mature neointima at 28 days. In mice lacking IL-1R1, the neointima was 64% smaller than that in wild-type controls at the 28-day timepoint, in agreement with other models. Conclusion This is the first description of a successful model of murine in situ stenting, using a stent specifically tailored for use in small thin-walled arteries. The procedure can be undertaken by a single operator without the need for an advanced level of microsurgical skill and is reliable and reproducible. The utility of this model is demonstrated by a reduction in in-stent restenosis in IL-1R1-deficient mice.

  • 出版日期2010-1-1