摘要

Once-through steam generator (OTSG) is one of the main equipments of ACPR50S small modular reactor. High flux of neutrons in OTSG will cause steam activation, increase the dose rate at main steam outlet, thus polluting entire secondary loop of the reactor. We carried out a preliminary analysis of 16N generation and transport based on physical calculation of current Shielding design of OTSG. The results show that the neutron flux magnitude in the OTSG has been reduced to a low level. Activity of 16N in the OTSG outlet is approximately tens of Bq/cm3.The results indicate that the material and thickness of current shielding structure of OTSG is satisfactory to meet the preliminary design goal under normal operating conditions.

全文