摘要

Disinfection of wastewater is vital in addressing the potential health risks of urban water reuse. To compare the applicability of wastewater disinfection methods other than chlorine, identical pilot plants that used ultraviolet (UV) irradiation and chlorine dioxide (ClO2) dosing were installed at municipal wastewater treatment plants in Shanghai, China and Darmstadt, Germany. The investigation included public health and environmental aspects associated with the two disinfection methods. The results of the pilot-scale studies suggest that, in order to comply with Chinese water quality standards for urban water reuse, it is advisable to have a tertiary treatment before wastewater disinfection. Both methods were able to achieve a 4 log(10) reduction in both total coliforms and Escherichia coli (E. coli). There was no evidence for regrowth of E. coli. However, after an initial 3 log(10) reduction, HPC increased within 48 h by more than 10-fold after UV irradiation as well as after low doses of ClO2. An increase in acute toxicity was detected after dosing with ClO2 but not after UV irradiation.