Analytical evaluation of a new point of care system for measuring cardiac Troponin I

作者:Kemper Danielle W M*; Semjonow Veronique; de Theije Femke; Keizer Diederick; van Lippen Lian; Mair Johannes; Wille Bernadette; Christ Michael; Geier Felicitas; Hausfater Pierre; Pariente David; Scharnhorst Volkher; Curvers Joyce; Nieuwenhuis Jeroen
来源:Clinical Biochemistry, 2017, 50(4-5): 174-180.
DOI:10.1016/j.clinbiochem.2016.11.011

摘要

Objectives: Point-of-care cardiac troponin testing with adequate analytical performances has the potential to improve chest pain patients flow in the emergency department. We present the analytical evaluation of the newly developed Philips Minicare cTnl point-of-care immunoassay. Design & methods: Li-heparin whole blood and plasma were used to perform analytical studies. The sample type comparison study was performed at 4 different hospitals. The 99th percentile upper reference limit (URL) study was performed using Li-heparin plasma, Li-heparin whole blood and capillary blood samples from 750 healthy adults, aging from 18 to 86 years. Results: Limit of the blank, limit of detection and limit of quantitation at 20% coefficient of variation (CV) were determined to be 8.5 ng/L, 18 ng/L and 38 ng/L respectively without significant differences between whole blood and plasma for LoQ. Cross-reactivity and interferences were minimal and no high-dose hook was observed. Total CV was found to be from 7.3% to 12% for cTnI concentrations between 109.6 and 6135.4 ng/L. CV at the 99th percentile URL was 18.6%. The sample type comparison study between capillary blood, Li heparin whole blood and Li-heparin plasma samples demonstrated correlation coefficients between 0.99 and 1.00 with slopes between 1.03 and 1.08. The method comparison between Minicare cTnI and Beckman Coulter Access, AccuTnI + 3 demonstrated a correlation coefficient of 0.973 with a slope of 1.09. The 99th percentile URL of a healthy population was calculated to be 43 ng/L with no significant difference between genders or sample types. Conclusions: The Minicare cTnI assay is a sensitive and precise, clinical usable test for determination of cTnI concentration that can be used in a near-patient setting as an aid in the diagnosis of acute myocardial infarction. (C) 2016 The Authors. Published by Elsevier Inc. on behalf of The Canadian Society of Clinical Chemists. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

  • 出版日期2017-3