Determination of bevantolol in human plasma using liquid chromatography-electrospray ionization tandem mass spectrometry and its application to a bioequivalence study

作者:Ren, Li; Wang, Zheng; Lou, Yiceng; Zheng, Lu; Zheng, Heng*; Yin, Chunping
来源:Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 2014, 959: 16-21.
DOI:10.1016/j.jchromb.2014.03.040

摘要

A liquid chromatography-electrospray ionization tandem mass spectrometry method was established and validated for the determination of bevantolol in human plasma using propranolol as the internal standard. The optimal chromatographic behavior of bevantolol and propranolol was achieved on a Welch Ultimate XB-C-18 column (5 mu m, 150 mm x 2.1 mm, Maryland, USA) with a mobile phase of acetonitrile-water (40:60, v/v) containing 10 mM ammonium acetate and 0.1% formic acid. The mass spectrometer was operated in selected reaction monitoring mode using the transition m/z 346.1 > 165.1 for bevantolol and m/z 260.3 > 116.1 for propranolol. Sample preparation was carried out through protein precipitation with acetonitrile. The calibration curves were linear over the range of 5.00-1000 ng/ml. The intra- and inter-day pretisions were less than 6.7% and 6.6%, respectively. This method was successfully applied to the bioequivalence study of two kinds of bevantolol hydrochloride tablets in 24 Chinese male volunteers in fasting and postprandial experiment.