Measuring issues in the GEM detector system for fusion plasma imaging

作者:Czarski T*; Chernyshova M; Malinowski K; Pozniak K T; Kasprowicz G; Kolasinski P; Krawczyk R; Wojenski A; Linczuk P; Zabolotny W; Jardin A; Mazon D; Jakubowska K; Boutoux G; Burgy F; Hulin S; Batani D
来源:Journal of Instrumentation, 2018, 13(08): C08001.
DOI:10.1088/1748-0221/13/08/C08001

摘要

A measurement systems based on GEM(Gas Electron Multiplier) detectors is developed for X-ray diagnostics of tokamak plasmas. The multi-channel setup is designed for evaluation the X-ray source distribution in energy, space and time. The paper deals with the development of a fast analysis and elaboration of collected data, including charge cluster identification and the separation of coincided signals. The proposed algorithm can be applied iteratively for series of superimposed pulses. On-line separation of overlapped signals was implemented applying the FPGA (FPGA -Field-Programmable Gate Array) technology with relatively simple firmware processing. We demonstrate reconstruction of coinciding signals and retrieval of radiation source properties and energy spectra.

  • 出版日期2018-8
  • 单位中国地震局