Design and cold test of S-BAND cavity BPM for HLS

作者:Luo Qing*; Sun BaoGen; Jia QiKa; He DuoHui; Fang Jia
来源:Science China Physics,Mechanics & Astronomy, 2011, 54: S292-S295.
DOI:10.1007/s11433-011-4555-y

摘要

An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 mu m.

全文