摘要

An Amberlite XAD-2 (XAD2) and titanium dioxide nanoparticles (TNPs) modified glassy carbon paste electrode (XAD2-TNP-GCPE) was developed for the determination of imipramine (IMI), trimipramine (TRI) and desipramine (DES). The electrochemical behavior of these molecules was investigated employing cyclic voltammetry (CV), chronocoulometry (CC), electrochemical impedance spectroscopy (EIS) and adsorptive stripping differential pulse voltammetry (AdSDPV). After optimization of analytical conditions using a XAD2-TNP-GCPE electrode at pH 6.0 phosphate buffer (0.1 M), the peak currents were found to vary linearly with its concentration in the range of 1.30 x 10(-9) to 6.23 x 10(-6) M for IMI, 1.16 x 10(-9) to 6.87 x 10(-6) M for TRI and 1.43 x 10(-9) to 5.68 x 10(-6) M for DES. The detection limits (S/N = 3) of 3.93 x 10(-10), 3.51 x 10(-10) and 4.35 x 10(-10) M were obtained for IMI, TRI and DES respectively using AdSDPV. The prepared modified electrode showed several advantages such as a simple preparation method, high sensitivity, very low detection limits and excellent reproducibility. The proposed method was employed for the determination of IMI, TRI and DES in pharmaceutical formulations, blood serum and urine samples.

  • 出版日期2013