Automatic string generation for estimating in vivo length changes of the medial patellofemoral ligament during knee flexion

作者:Graf Matthias; Diether Salomon; Vlachopoulos Lazaros; Fucentese Sandro; Fuernstahl Philipp
来源:MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2014, 52(6): 511-520.
DOI:10.1007/s11517-014-1156-8

摘要

Modeling ligaments as three-dimensional strings is a popular method for in vivo estimation of ligament length. The purpose of this study was to develop an algorithm for automated generation of non-penetrating strings between insertion points and to evaluate its feasibility for estimating length changes of the medial patellofemoral ligament during normal knee flexion. Three-dimensional knee models were generated from computed tomography (CT) scans of 10 healthy subjects. The knee joint under weight-bearing was acquired in four flexion positions (0A degrees-120A degrees). The path between insertion points was computed in each position to quantify string length and isometry. The average string length was maximal in 0A degrees of flexion (64.5 +/- A 3.9 mm between femoral and proximal patellar point; 62.8 +/- A 4.0 mm between femoral and distal patellar point). It was minimal in 30A degrees (60.0 +/- A 2.6 mm) for the proximal patellar string and in 120A degrees (58.7 +/- A 4.3 mm) for the distal patellar string. The insertion points were considered to be isometric in 4 of the 10 subjects. The proposed algorithm appears to be feasible for estimating string lengths between insertion points in an automatic fashion. The length measurements based on CT images acquired under physiological loading conditions may give further insights into knee kinematics.

  • 出版日期2014-6