A Phase III, Open-Label, Single-Arm Study of Tenecteplase for Restoration of Function in Dysfunctional Central Venous Catheters

作者:Tebbi Cameron*; Costanzi John; Shulman Robert; Drei**ach Luke; Jacobs Brian R; Blaney Martha; Ashby Mark; Gillespie Barbara S; Begelman Susan M
来源:Journal of Vascular and Interventional Radiology, 2011, 22(8): 1117-1123.
DOI:10.1016/j.jvir.2011.02.034

摘要

Purpose: To evaluate, in a phase III, single-arm study, the safety and efficacy of the thrombolytic agent tenecteplase in restoring function to dysfunctional central venous catheters (CVCs).
Materials and Methods: Pediatric and adult patients with dysfunctional CVCs were eligible to receive as much as 2 mL (2 mg) of intraluminal tenecteplase, which was left to dwell in the CVC lumen for a maximum of 120 minutes. If CVC function was not restored at 120 minutes, a second dose was instilled for an additional 120 minutes.
Results: Tenecteplase was administered to 246 patients. Mean patient age was 44 years (range, 0-92 y); 72 patients (29%) were younger than 17 years of age. Chemotherapy was the most common reason for catheter insertion. Restoration of CVC function was achieved in 177 patients (72%) within 120 minutes after the first dose. After instillation of a maximum of two doses of tenecteplase, CVC function was restored in 200 patients (81%), with similar frequencies in pediatric (83%) and adult (80%) patients. Adverse events (AEs) were reported in 31 patients (13%); fever (2%), neutropenia (1%), and nausea (0.8%) were most common. One serious AE, an allergic hypersensitivity reaction, was judged to be related to tenecteplase and/or a chemotherapeutic agent that the patient was receiving concurrently.
Conclusions: Consecutive administration of one or two doses of tenecteplase into CVCs showed efficacy in the restoration of catheter function in patients with dysfunctional CVCs.