MR spectroscopy as a tool for in vivo determination of steatosis in liver transplant recipients

作者:Hajek Milan*; Dezortova Monika; Wagnerova Dita; Skoch Antonin; Voska Ludek; Hejlova Irena; Trunecka Pavel
来源:Magnetic Resonance Materials in Physics Biology and Medicine, 2011, 24(5): 297-304.
DOI:10.1007/s10334-011-0264-9

摘要

Object Among several non-invasive methods of liver fat analysis, the most important role is played by MR imaging and spectroscopy (MRS). This study describes the 1H MRS at 3T measurement of liver fat volume fraction phi(fat) in a group of liver transplant patients, an at-risk group for the development of de novo steatosis.
Materials and methods Seventy-seven liver transplant recipients-who underwent routine protocolar posttransplant examination were divided into three groups: CON-PAT (control group for the cross validation test, 48 patients), PAT-PAT (patients test group for the cross validation test, 29 patients), and PAT (pooled data). Single voxel 1H MRS at 3T was used for the determination of phi(fat) and histology results (His) were used as the reference standard.
Results Linear and non-linear regression models were used to describe the relationship between phi(fat) and His. Strong correlation was found for both models with r = 0.83-0.94 (P < 0.001); a higher r was found for non-linear regression in all tested groups. Areas under receiver operation curves were calculated for cut points His >= 5 and > 33% and were found in the range of 0.77-0.86. Fibrosis influences the calculation of phi(fat) and different slopes were obtained for fibrosis stages F0-F1 and F2-F3, respectively.
Conclusion Significant correlation was found between the results of histology and 1H MRS measurement of liver fat content. The method is suitable for non-invasive repetitive examination of liver fat in liver-transplants patients between protocol biopsies and for the screening of steatosis in other liver diseases.