摘要

We report a new analytical model of the MEMS-based thermal property sensor for samples which are difficult to handle and susceptible to damage by thermal stimulus, such as living cells. Many sensor designs had been reported for thermal property measurements, but only a few of them have considered the analytical model of the single-sided measurement in which a measurement sample is placed on the sensor substrate. Even in the few designs that have considered the analytical model, their applicable limits are restricted to more than 1 mm length in practical situations. Our new model considers both the sample and the sensor substrate thermal properties and is applicable to a sensor length less than 1 m. In order to minimize the influence of the heat stimulus to the sample, the model formulates the required heat dissipating time for different sensor geometries. We propose fast and precise detection circuit architecture to realize our model, and we discuss the sensor performance for a number of different designs.

  • 出版日期2018-4