摘要

In the case of unknown running-in oils, the direct reading ferrographs of oil samples were selected for analysis. By introducing the grey target theory, the standard mode was constructed. The quality order of running-in oils was determined through calculating the approaching degree, and the results were consistent to the real condition. Meanwhile, the study indicated that the selected criterion should reflect multi-factors and their relations to get the correct results.

全文