摘要

A detailed three-dimensional numerical model is used to compute the flow pattern and the flame behavior of thin solid fuels in a rectangular column that resembles a standard Limiting Oxygen Index (LOI) device. The model includes full Navier-Stokes equations for mixed buoyant-forced flow and finite rate combustion and pyrolysis reactions so that the sample LOI can be computed to study the effect of feeding flow rate, sample width and gravity levels. In addition to the above parameters, the sample location in the column and the column cross-sectional area are also investigated on their effect on the ambient air entrainment from the top.

  • 出版日期2012-12