摘要

This paper proposes a full engine cycle analysis to derive the schedule of variable guide vanes (VGVs) in a multi-stage axial compressor for improving the performance of a turbofan engine with required surge margin. Most researchers assumed the operating line of a compressor in process of scheduling of VGVs. However, it has been known that the performance of a compressor is influenced by the angle of VGVs. As a result, the performance variation of a compressor can affect an engine. Therefore, a full engine cycle analysis is conducted to consider the effect of VGVs on a turbofan engine. The VGVs are applied to the front stages of the high pressure compressor in the low-bypass ratio turbofan engine. The compressor of the front stages is transonic three-stage axial flow compressor. The commercial engine simulation program, NPSS (TM) is employed to analyze the on- and off-design performance of the turbofan engine. 1D meanline analysis is used for performance prediction of a multi-stage axial flow compressor with VGVs. The engine simulation program is coupled with the compressor performance prediction tool to consider the engine performance variation with application of the VGVs. The proposed scheduling algorithm of the inlet guide vane (IGV) and stator vanes (SV) is adjusting the vanes angle to have the minimum loss incidence angle at all rotor blades and to satisfy the required surge margin at off-design condition. The result shows that the proposed algorithm can obtain the scheduling of the IGV, 1st and 2nd SVs angle with stable operation and improved specific fuel consumption of the engine.

  • 出版日期2015-12