摘要

Objectives: To compare the performance of LFpen (DIAGNOdent pen) with two different wedge-shaped tips to conventional bitewing radiography (BW) for detecting proximal secondary caries at the cervical margin of amalgam restorations in vitro. %26lt;br%26gt;Methods: Seventy-five molars with class II amalgam restorations were selected. Depending on the marginal filling extension, data was subdivided into a crown group (C), when the filling ended in enamel, and into a root group (R), when the filling ended beyond the cementum-enamel junction. Bayesian analysis including calculation of the area under the receiver operating curve (AUC) was performed. Furthermore, Spearman correlations between caries and cofactors, such as presence of plaque or stain, occlusal ditching, marginal gap size, filling overhangs, and shortfalls, were calculated. Additionally, for group R the correlation coefficient between LFpen measurements and lesion depth was calculated. Histology served as gold standard. %26lt;br%26gt;Results: In group C both at the D1 and D3 levels, LFpen with two different tips showed a better performance than bitewing radiography (AUC at D1: 0.83/0.79 (LFpen) and 0.63 (BW); at D3:0.66/0.66 (LFpen) and 0.53 (BW)). In group R, the respective AUC valueswere 0.53/0.56 (LF) and 0.59 (BW). A significant medium correlation was observed for occlusal ditching and proximal caries. Stain accumulation at the restoration margins especially in combination with filling overhangs interfered with LFpen readings, resulting in false positive measurements. %26lt;br%26gt;Conclusions: Compared to BW, LFpen enhances the detection of secondary caries lesions at the cervical margin of amalgam restorations that do not extend below the cementum-enamel junction.

  • 出版日期2012-6