Multimodal Visibility (Radiography, Computed Tomography, and Magnetic Resonance Imaging) of Microspheres for Transarterial Embolization Tested in Porcine Kidneys

作者:Sommer Christof M*; Stampfl Ulrike; Bellemann Nadine; Holzschuh Maria; Kueller Alexander; Bluemmel Jaques; Gehrig Tobias; Shevchenko Maxym; Kenngott Hannes G; Kauczor Hans U; Pereira Philippe L; Radeleff Boris A
来源:Investigative Radiology, 2013, 48(4): 213-222.
DOI:10.1097/RLI.0b013e31827f6598

摘要

Objective: The objective of this study was to test multimodal visibility (radiography, computed tomography [CT], and magnetic resonance imaging [MRI]) of microspheres for transarterial embolization in porcine kidneys. Materials and Methods: Currently available embolization particles (microspheres) were modified. A dense x-ray material (barium sulfate) was added to create visibility for radiography and CT. A magnetic substance (iron oxide) was additionally added to create visibility for MRI. This chemical modification was performed for particles with sizes of 100 +/- 25 and 700 +/- 50 mu m. Three different prototypes per size class (samples A, B, and C) resulted, each with a different degree of barium sulfate but with the same degree of iron oxide. The currently available embolization particles with sizes of 100 +/- 25 and 700 +/- 50 mu m were used as controls (sample control). Eight renal arteries of 4 pigs were embolized. Study end points were size distribution evaluated in vitro as well as qualitative and quantitative particle visibility evaluated in vivo. Results: The size distribution of the particles with a size of 100 +/- 25 mu m was between 96 +/- 11 mu m for sample A and 102 +/- 13 mu m for the sample control without significant differences (n.s.). The size distribution of the particles with a size of 700 +/- 50 mu m was between 691 +/- 20 mu m for sample A and 716 +/- 34 mu m for sample C without significant differences (n.s.). For radiography, the particles with sizes of 100 +/- 25 and 700 +/- 50 mu m for samples A, B, and C were definitely visible during the embolization. The sample control was definitely not visible. For CT and MRI (T1-weighted [T1w] and T2-weighted [T2w]), the particles with sizes of 100 +/- 25 and 700 +/- 50 mu m for samples A, B, and C were definitely visible after the embolization. The sample control was definitely not visible. For CT, the signal-to-noise ratio for samples A, B, and C increased significantly after the embolization (eg, sample A, particles with a size of 100 +/- 25 mu m: 66.5% +/- 23.7%, P < 0.05). The signal-to-noise ratio for the sample control did not change after the embolization (eg, sample control, particles with a size of 700 +/- 25 mu m: -0.2% +/- 15.2%, n.s.). For MRI (T1w and T2w), the signal-to-noise ratio for samples A, B, and C decreased significantly after the embolization (eg, sample B, particles with a size of 700 +/- 50 mu m, T1w: -72.9% +/- 6.6%; P < 0.05). The signal-to-noise ratio for the sample control did not change after the embolization (eg, sample control, particles with a size of 100 +/- 25 mu m, T2w: 6.2% +/- 16.1%, n.s.). Conclusions: In this study, the chemical modification of the currently available microspheres for transarterial embolization resulted in a size distribution comparable with the currently available microspheres and created multimodal visibility for radiography, CT, and MRI.

  • 出版日期2013-4