Detection of Gastroesophageal Reflux in Children Using Combined Multichannel Intraluminal Impedance and pH Measurement: Data from the German Pediatric Impedance Group

作者:Pilic Denisa*; Froehlich Thorsten; Noeh Frank; Pappas Angeliki; Schmidt Choudhury Anjona; Koehler Henrik; Skopnik Heino; Wenzl Tobias G
来源:Journal of Pediatrics, 2011, 158(4): 650-U163.
DOI:10.1016/j.jpeds.2010.09.033

摘要

Objective To validate the use of combined multichannel intraluminal impedance (MII)-pH (MII-pH) monitoring for detecting gastroesophageal reflux (GER) in children in daily clinical practice.
Study design The patients were divided into 3 symptom groups based on the main indication for the procedure. MII-pH monitoring was performed in 700 children presenting with symptoms suggestive of GER, including 329 children with pulmonary symptoms, 325 with gastrointestinal symptoms, and 46 with neurologic symptoms. The MII-pH results were compared with pH monitoring alone, and retrograde bolus movements, symptom index, and symptom association probability were compared.
Results Overall, 270 measurements were abnormal: 101 (37%) showed abnormal MII-pH study, 49 (18%) showed only pathological pH measurements and 120 measurements (45%) had an abnormal MII recording only. Extraintestinal symptoms of GER were seen more often in younger children and were more often related to a normal pH study but an abnormal MII study. Infants had a significantly higher number of retrograde bolus movements than older children. Symptom index and symptom association probability showed moderate agreement (Cohen kappa, 0.54).
Conclusions From this large systematically standardized data collection of MII-pH measurements in children, we conclude that 45% of the patients with abnormal GER would not have been recognized by 24-hour pH measurement alone. Our findings confirm that MII-pH is superior to pH monitoring alone in detecting GER. (J Pediatr 2011; 158:650-4).

  • 出版日期2011-4