摘要

In vitro cytotoxicity assays are essential tools in the screening of engineered nanomaterials (NM) for cellular toxicity. The resazurin live cell assay is widely used because it is non-destructive and is well suited for high-throughput platforms. However, NMs, in particular carbon nanotubes (CNT) can interfere in assays through quenching of transmitted light or fluorescence. We show that using the resazurin assay with time-point reading of clarified supernatants resolves this problem. Human lung epithelial (A549) and murine macrophage (J774A.1) cell lines were exposed to NMs in 96-well plates in 200 mu L. of media/well. After 24 h incubation, 100 mu L of supernatant was removed, replaced with resazurin reagent in culture media and aliquots at 10 min and 120 min were transferred to black-wall 96-well plates. The plates were quick-spun to sediment the residual CNTs and fluorescence was top-read (lambda(Ex) = 540 nm, lambda(Em) = 600 nm). The procedure was validated for CNTs as well as silica nanoparticles (SiNP). There was no indication of reduction of resazurin by the CNTs. Stability of resorufin, the fluorescent product of the resazurin reduction was then assessed. We found that polar CNTs could decrease the fluorescence signal for resorufin, possibly through oxidation to resazurin or hyper-reduction to hydroxyresorufin. This effect can be easily quantified for elimination of the bias. We recommend that careful consideration must be given to fluorimetric/colorimetric in vitro toxicological assessments of optically/chemically active NMs in order to relieve any potential artifacts due to the NMs themselves.

  • 出版日期2015-2