Arthroscopic Mosaicplasty for Osteochondral Lesions of the Knee: Computer-Assisted Navigation Versus Freehand Technique

作者:Di Benedetto Paolo; Citak Mustafa*; Kendoff Daniel; O' Loughlin Padhraig F; Suero Eduardo M; Pearle Andrew D; Koulalis Dimitrios
来源:Arthroscopy-The Journal of Arthroscopic and Related Surgery, 2012, 28(9): 1290-1296.
DOI:10.1016/j.arthro.2012.02.013

摘要

Purpose: The purpose of this study was to compare a freehand arthroscopic approach versus mosaicplasty for treatment of osteochondral lesions of the knee with a navigated arthroscopic technique. Methods: Four whole cadaveric lower limbs were used. A conventional navigation system was used in combination with an autologous osteochondral graft transplantation system (Osteochondral Autograft Transfer System [OATS]; Arthrex, Naples, FL). The congruity of the articular surface was measured with the navigation probe to detect any difference between the surface created by the grafts and the surface of the femoral condyle surrounding them. The angle relates to a line perpendicular to the articular surface. This line is made by the cutting instrument for graft harvesting and insertion and the articular surface. Results: The mean angle of graft harvest was 3.4 degrees (range, 0 degrees to 10 degrees) in the navigated group versus 14.8 degrees (range, 6 degrees to 26 degrees) in the freehand group (P %26lt; .0003). The mean angle for recipient-site coring was 1.5 degrees (range, 0 degrees to 5 degrees) in the navigated group versus 12.6 degrees (range, 4 degrees to 17 degrees) in the freehand group (P %26lt; .0003). The mean angle of graft placement was 2 degrees (range, 1 degrees to 5 degrees) in the navigated group versus 10.8 degrees (range, 5 degrees to 15 degrees) in the freehand group (P = .0002). The mean protrusion height of the plug was 0.23 mm (range, 0.1 to 0.5 mm; SD, 0.16) in the navigated group versus 0.34 mm (range, 0.0 to 0.7 mm; SD, 0.25) in the freehand group (P = .336). Conclusions: Computer-assisted arthroscopic mosaicplasty for treatment of osteochondral lesions in the cadaveric model presented in this study allows permanent visualization of the angle of recipientsite preparation, the depth of the donor plug and the recipient plug, and the angle of insertion of the graft at the recipient site. Clinical Relevance: This study shows evidence of potentially greater precision and reproducibility of navigated arthroscopic mosaicplasty when compared with an arthroscopic freehand technique in a cadaveric model. However, true clinical outcome benefit will only be elucidated upon performance of appropriate clinical studies.

  • 出版日期2012-9