Development of multiple-eye PIV using mirror array

作者:Maekawa Akiyoshi; Sakakibara Jun*
来源:Measurement Science and Technology, 2018, 29(6): 064011.
DOI:10.1088/1361-6501/aab9f7

摘要

In order to reduce particle image velocimetry measurement error, we manufactured an ellipsoidal polyhedral mirror and placed it between a camera and flow target to capture n images of identical particles from n (=80 maximum) different directions. The 3D particle positions were determined from the ensemble average of C-n(2) intersecting points of a pair of line-of-sight back-projected points from a particle found in any combination of two images in the n images. The method was then applied to a rigid-body rotating flow and a turbulent pipe flow. In the former measurement, bias error and random error fell in a range of +/- 0.02 pixels and 0.02-0.05 pixels, respectively; additionally, random error decreased in proportion to n(-037). In the latter measurement, in which the measured value was compared to direct numerical simulation, bias error was reduced and random error also decreased in proportion to n(-0.40).

  • 出版日期2018-6