Atrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial

作者:Boriani Giuseppe*; Tukkie Raymond; Manolis Antonis S; Mont Lluis; Puererfellner Helmut; Santini Massimo; Inama Giuseppe; Serra Paolo; de Sousa Joao; Botto Giovanni Luca; Mangoni Lorenza; Grammatico Andrea; Padeletti Luigi
来源:European Heart Journal, 2014, 35(35): 2352-2362.
DOI:10.1093/eurheartj/ehu165

摘要

Aims Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard dual-chamber pacing (Control DDDR). Methods and results In a randomized, parallel, single-blind, multi-centre trial we enrolled 1300 patients with bradycardia and previous atrial tachyarrhythmias, in whom a DDDRP pacemaker had recently been implanted. History of permanent AF and third-degree atrioventricular block were exclusion criteria. After a 1-month run-in period, 1166 eligible patients, aged 74 +/- 9 years, 50% females, were randomized to Control DDDR, DDDRP + MVP, or MVP. Analysis was intention-to-treat. The primary outcome, i.e. the 2-year incidence of a combined endpoint composed of death, cardiovascular hospitalizations, or permanent AF, occurred in 102/385 (26.5%) Control DDDR patients, in 76/383 (19.8%) DDDRP + MVP patients [hazard ratio (HR) = 0.74, 95% confidence interval 0.55-0.99, P = 0.04 vs. Control DDDR] and in 85/398 (21.4%) MVP patients (HR = 0.89, 95% confidence interval 0.77-1.03, P = 0.125 vs. Control DDDR). When compared with Control DDDR, DDDRP + MVP reduced the risk for AF longer than 1 day (HR = 0.66, 95% CI 0.52-0.85, P < 0.001), AF longer than 7 days (HR = 0.52, 95% CI 0.36-0.73, P < 0.001), and permanent AF (HR = 0.39, 95% CI 0.21-0.75, P = 0.004). Conclusion In patients with bradycardia and atrial tachyarrhythmias, DDDRP + MVP is superior to standard dual-chamber pacing. The primary endpoint was significantly lowered through the reduction of the progression of atrial tachyarrhythmias to permanent AF. NCT00262119.

  • 出版日期2014-9-14