AntiEpileptic drug Monitoring in PREgnancy (EMPiRE): a double-blind randomised trial on effectiveness and acceptability of monitoring strategies

作者:Thangaratinam Shakila*; Marlin Nadine; Newton Sian; Weckesser Annalise; Bagary Manny; Greenhill Lynette; Rikunenko Rachel; D'Amico Maria; Rogozinska Ewelina; Kelso Andrew; Hard Kelly; Coleman Jamie; Moss Ngawai; Roberts Tracy; Middleton Lee; Dodds Julie; Pullen Angela; Eldridge Sandra; Pirie Alexander; Denny Elaine; McCorry Doug; Khan Khalid S
来源:Health Technology Assessment, 2018, 22(23): 1-+.
DOI:10.3310/hta22230

摘要

Background: Pregnant women with epilepsy on antiepileptic drugs (AEDs) may experience a reduction in serum AED levels. This has the potential to worsen seizure control.
Objective: To determine if, in pregnant women with epilepsy on AEDs, additional therapeutic drug monitoring reduces seizure deterioration compared with clinical features monitoring after a reduction in serum AED levels.
Design: A double-blind, randomised trial nested within a cohort study was conducted and a qualitative study of acceptability of the two strategies was undertaken. Stratified block randomisation with a 1 : 1 allocation method was carried out.
Setting: Fifty obstetric and epilepsy clinics in secondary and tertiary care units in the UK.
Participants: Pregnant women with epilepsy on one or more of the following AEDs: lamotrigine, carbamazepine, phenytoin or levetiracetam. Women with a >= 25% decrease in serum AED level from baseline were randomised to therapeutic drug monitoring or clinical features monitoring strategies.
Interventions: In the therapeutic drug monitoring group, clinicians had access to clinical findings and monthly serum AED levels to guide AED dosage adjustment for seizure control. In the clinical features monitoring group, AED dosage adjustment was based only on clinical features.
Main outcome measures: Primary outcome - seizure deterioration, defined as time to first seizure and to all seizures after randomisation per woman until 6 weeks post partum. Secondary outcomes - pregnancy complications in mother and offspring, maternal quality of life, seizure rates in cohorts with stable serum AED level, AED dose exposure and adverse events related to AEDs.
Analysis: Analysis of time to first and to all seizures after randomisation was performed using a Cox proportional hazards model, and multivariate failure time analysis by the Andersen-Gill model. The effects were reported as hazard ratios (HRs) with 95% confidence intervals (CIs). Secondary outcomes were reported as mean differences (MDs) or odds ratios.
Results: A total of 130 women were randomised to the therapeutic drug monitoring group and 133 to the clinical features monitoring group; 294 women did not have a reduction in serum AED level. A total of 127 women in the therapeutic drug monitoring group and 130 women in the clinical features monitoring group (98% of complete data) were included in the primary analysis. There were no significant differences in the time to first seizure (HR 0.82, 95% CI 0.55 to 1.2) or timing of all seizures after randomisation (HR 1.3, 95% CI 0.7 to 2.5) between both trial groups. In comparison with the group with stable serum AED levels, there were no significant increases in seizures in the clinical features monitoring (odds ratio 0.93, 95% CI 0.56 to 1.5) or therapeutic drug monitoring group (odds ratio 0.93, 95% CI 0.56 to 1.5) associated with a reduction in serum AED levels. Maternal and neonatal outcomes were similar in both groups, except for higher cord blood levels of lamotrigine (MD 0.55 mg/l, 95% CI 0.11 to 1 mg/l) or levetiracetam (MD 7.8 mg/l, 95% CI 0.86 to 14.8 mg/l) in the therapeutic drug monitoring group than in the clinical features monitoring group. There were no differences between the groups on daily AED exposure or quality of life. An increase in exposure to lamotrigine, levetiracetam and carbamazepine significantly increased the cord blood levels of the AEDs, but not maternal or fetal complications. Women with epilepsy perceived the need for weighing up their increased vulnerability to seizures during pregnancy against the side effects of AEDs.
Limitations: Fewer women than the original target were recruited.
Conclusion: There is no evidence to suggest that regular monitoring of serum AED levels in pregnancy improves seizure control or affects maternal or fetal outcomes.
Future work recommendations: Further evaluation of the risks of seizure deterioration for various threshold levels of reduction in AEDs and the long-term neurodevelopment of infants born to mothers in both randomised groups is needed. An individualised prediction model will help to identify those women who need close monitoring in pregnancy.

  • 出版日期2018-5