Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations

作者:Leung Cynthia C; Palomo Leena; Griffith Richard; Hans Mark G*
来源:American Journal of Orthodontics and Dentofacial Orthopedics, 2010, 137(4): S109-S119.
DOI:10.1016/j.ajodo.2009.07.013

摘要

Introduction: The purpose of this study was to evaluate the accuracy and reliability of cone-beam computed tomography (CBCT) in the diagnosis of naturally occurring fenestrations and bony dehiscences. In addition, we evaluated the accuracy and reliability of CBCT for measuring alveolar bone margins. Methods: Thirteen dry human skulls with 334 teeth were scanned with CBCT technology. Measurements were made on each tooth in the volume-rendering mode from the cusp or incisal tip to the cementoenamel junction and from the cusp or incisal tip to the bone margin along the long axis of the tooth. The accuracy of the CBCT measurements was determined by comparing the means, mean differences, absolute mean differences, and Pearson correlation coefficients with those of direct measurements. Accuracy for detection of defects was determined by using sensitivity and specificity. Positive and negative predictive values were also calculated. Results: The CBCT measurements showed mean deviations of 0.1 +/- 0.5 mm for measurements to the cementoenamel junction and 0.2 +/- 1.0 mm to the bone margin. The absolute values of the mean differences were 0.4 +/- 0.3 mm for the cementoenamel junction and 0.6 +/- 0.8 mm for the bone margin. The sensitivity and specificity of CBCT for fenestrations were both about 0.80, whereas the specificity for dehiscences was higher (0.95) and the sensitivity lower (0.40). The negative predictive values were high (>= 0.95), and the positive predictive values were low (dehiscence, 0.50; fenestration, 0.25). The reliability of all measurements was high (r >= 194). Conclusions: By using a voxel size of 0.38 mm at 2 mA, CBCT alveolar bone height can be measured to an accuracy of about 0.6 mm, and root fenestrations can be identified with greater accuracy than dehiscences. (Am J Orthod Dentofacial Orthop 2010;137:S109-19)

  • 出版日期2010-4