摘要

Orthogonal projection sampling mode was proposed to reconstruct the incomplete-data flow field in optical computerized tomography (OCT). With numerical simulation technique, a two-peak plane symmetric flow field was reconstructed in different sampling modes and discussed in simulated results is the reconstructive accuracy with error indexes, such as mean square error (MSE) and peak error (PE). The corresponding experiments were researched with a Fabry-Perot rotary interferometer. The results indicated that the errors were drastically reduced and the precision was improved when orthogonal projection sampling mode was adopted in the reconstruction of the incomplete data field. The MSE obtained with orthogonal sampling mode was decreased 72.81% from that of the sequential projection sampling mode (the difference between the MSE obtained with the orthogonal sampling mode and that with the sequential sampling mode divided by the MSE of the sequential sampling mode) and the PE was decreased by 73.97%. The precision obtained from the experimental results reached 10%, which showed the orthogonal projection sampling could be a practicable sampling mode for the incomplete data field reconstruction in OCT and could provide some guidance for the flow-field measurement and apparatus design in the practical situation.