摘要

In this work pre-operating tests of low-cost building structures have been presented. A hybrid experimental-numerical methodology has been used to determine the influence of an external, environmental load on the overall endurance of a hangar made of self-supporting metal-plates. Numerical simulations carried out on a FEM model have been consequently verified by measurements of the structure performed with the 3D Digital Image Correlation method and as a result, a detailed, calibrated FEM model of the structure has been developed.

  • 出版日期2012-11