Feasibility of Routinely Using Hydrogen Peroxide Vapor to Decontaminate Rooms in a Busy United States Hospital

作者:Otter Jonathan A*; Puchowicz Matthew; Ryan David; Salkeld James A G; Cooper Timothea A; Havill Nancy L; Tuozzo Kathy; Boyce John M
来源:Infection Control and Hospital Epidemiology, 2009, 30(6): 574-577.
DOI:10.1086/597544

摘要

During a 22-month period at a 500-bed teaching hospital, 1,565 rooms that had housed patients infected with multidrug-resistant pathogens were decontaminated using hydrogen peroxide vapor. Hydrogen peroxide vapor decontamination required a mean time of 2 hours and 20 minutes, compared with 32 minutes for conventional cleaning. Despite the greater time required for decontamination, hydrogen peroxide vapor decontamination of selected patient rooms is feasible in a busy hospital with a mean occupancy rate of 94%.

  • 出版日期2009-6